Full-arch scan bodies · Full Arch Technologies, UK

Scan Ladder

Full-arch scanning, simplified.

Titanium scan bodies for All-on-X cases, designed to help your intraoral scanner register every implant position across the arch. Open to any scanner, with one open CAD library.

Scan Ladder titanium scan bodies seated on a full-arch model
Scan Ladder scan bodies on a model under studio light

The full-arch challenge

A long span. Fewer landmarks.

Across an edentulous arch, repeated shapes can make scan frames harder to distinguish. Scan Ladder adds recognisable geometry: a non-repeating surface and individual landmarks designed to help the scanner identify each scan body as it moves across the arch.

Design

Four details. One purpose.

Distinct references for scanning. A shared reference for CAD.

Scan Ladder titanium scan bodies seated on a full-arch model
  1. Randomised surface

    A patented, non-repeating surface gives the scanner distinct reference points instead of symmetrical patterns it could mismatch.

    Close-up of the randomised dimpled titanium surface
  2. Individual shapes

    Each scan body carries its own geometric feature, such as a hexagon, sphere or cube, so its position can be identified without confusion.

    Close-up of distinct geometric landmarks on neighbouring scan bodies
  3. Notches

    Notches along the edges help prevent rotation and duplication errors.

    Close-up of the notches along the edge of a scan body
  4. One common cylinder

    Every scan body shares the same central cylinder, so one CAD library serves every platform. Only the screw thread changes.

    Close-up of the central cylinder shared by every scan body

Technology

One open library. Any scanner.

CAD software overlaying the common-cylinder library on scanned Scan Ladder bodies
  • Open to any scanner

    Medical-grade titanium with a roughened outer surface for easy pickup on any intraoral scanner.

  • One common library

    A single common-cylinder library across implant platforms keeps CAD alignment simple to verify.

  • Exocad, 3Shape and Medit Design

    The open, standardised library works with major design software and is lab-friendly.

  • Medit SmartX

    Medit users can switch on SmartX Smart Matching for implant cases, as the manufacturer’s scanning instructions recommend.

Clinical workflow

From placement to design.

  1. Clinician seating a Scan Ladder scan body in the mouth

    Place

    Seat the scan bodies on the multi-unit abutments, using the screw size for your implant system.

  2. Intraoral scanner capturing Scan Ladder scan bodies

    Scan

    Scan with your intraoral scanner, capturing every cylinder completely.

  3. Digital scan of Scan Ladder bodies on a full arch

    Check

    Confirm full cylinder geometry, clear edges and no voids. Rescan any incomplete cylinder before exporting.

  4. CAD software aligning the library to the scanned bodies

    Design

    The lab matches the common-cylinder library in its CAD software and designs the full-arch restoration.

Always follow the manufacturer’s scanning instructions.Read the scanning instructions

The final restoration.

A full-arch restoration being seated. Final-result footage published by Scan Ladder.

Video by Scan Ladder · 5 seconds · muted

A gloved hand holding a full-arch restoration, photographed by Scan Ladder
Full-arch restoration pictured by Scan Ladder; illustrative product imagery, not the testimonial case.

Testimonial published by Scan Ladder

From the manufacturer’s community.

“My doc said his case was perfect! He’s shocked at how passive and easy the fit was!”

Jesse Flor

An individual account shared on the manufacturer’s website. It is not a USSUS Med customer testimonial or a guarantee of clinical results.

Read on Scan Ladder

Specifications

Technical details.

Manufacturer
Full Arch Technologies Limited, United Kingdom
Material
Medical-grade titanium (Grade 5) with a roughened outer surface
Kits
Titanium Direct Set with 6 or 8 scan bodies. The 8× set adds two extra-long scan bodies for distal implants.
Prosthetic screw sizes
1.4 mm, 1.6 mm and 1.72 mm, on a 4.8 mm platform
CAD library
One common-cylinder library for Exocad, 3Shape and Medit Design
Scanners
Open to any intraoral scanner
Scan Ladder kit packaging

Screw size and implant systems

Screw sizeExamples of compatible systems
1.4 mmmost commonOsstem, Nobel Biocare, DESS, Neodent, IPD, Straumann Bone Level, Ankylos, Megagen, BioHorizons, Camlog, Hiossen, Zimmer
1.6 mmMIS, Alfa Bio, Neoss, Thommen, Geass, Ditron, GP
1.72 mmDentium, Oxy Fixo, Implant Direct Legacy, Cowellmedi, Paltop, Geomedi

Examples from the manufacturer’s brochure. Confirm your implant system and connection on the manufacturer’s full compatibility list, or ask our team, before ordering. Full compatibility list

Pricing, availability and delivery in the UAE are confirmed by our sales team in your quotation.

The Scan Ladder range

Order the full range.

Scan body kits, TissueSync, LabSync, GuideLock and Rosen components, each with its exact Scan Ladder SKU. Confirmed prices include VAT. Sign in to order.

Scan Ladder GuideLock™ System

Digital solutions / Scan Ladder full-arch

Scan Ladder GuideLock™ System

Screw-retained, bone-anchored reference units that stabilise surgical guides in fully edentulous cases and give a fixed fiducial for dataset alignment.

2 configurations

Request a quotationper unit
Configure
Scan Ladder INDIRECT Kit

Digital solutions / Scan Ladder full-arch

Scan Ladder INDIRECT Kit

Single-use ABS scan ladders that clip onto existing scan bodies for full-arch scanning, in Mini, Small and Regular sizes. They can also be bonded into a verification jig.

Request a quotationper unit
View product
Scan Ladder LabSync, 1.4 mm

Digital solutions / Scan Ladder full-arch

Scan Ladder LabSync, 1.4 mm

LabSync accessory kit to duplicate the prosthesis with Scan Ladder: a dedicated exocad library reverses the multi-unit position once scanned. Six 1.4 mm components.

Request a quotationper unit
View product
Rosen screw packs

Digital solutions / Scan Ladder full-arch

Rosen screw packs

Packs of 8 Rosen prosthetic screws in 1.4 mm (Nobel compatible), 1.6 mm and 1.72 mm, used with Scan Ladder scan bodies. Check the screw width with your implant provider.

3 configurations

Request a quotationper unit
Configure
Rosen MUA Ti-Base and model analog

Digital solutions / Scan Ladder full-arch

Rosen MUA Ti-Base and model analog

Rosen CAD/CAM Ti-Base for multi-unit abutments, supplied with its screw, and the matching Rosen MUA model analog, as sold in the Scan Ladder range.

2 configurations

Request a quotationper unit
Configure
Scan Ladder TissueSync™ Scan Body Set

Digital solutions / Scan Ladder full-arch

Scan Ladder TissueSync™ Scan Body Set

Titanium TissueSync scan bodies to capture and align soft tissue in the Scan Ladder full-arch workflow. Six scan bodies and six screws with an autoclavable box.

3 configurations

Request a quotationper unit
Configure
Scan Ladder Direct Titanium All-on-X Scan Body Kit

Digital solutions / Scan Ladder full-arch

Scan Ladder Direct Titanium All-on-X Scan Body Kit

Reusable Grade 5 titanium scan bodies that fit directly on multi-unit abutments, with a randomised surface and one common CAD cylinder. Choose the connection and kit.

14 configurations

Request a quotationper unit
Configure
Scan Ladder ULTRA All-on-X Scan Body Kit

Digital solutions / Scan Ladder full-arch

Scan Ladder ULTRA All-on-X Scan Body Kit

The complete Scan Ladder full-arch kit: 8 Ultra titanium scan bodies, TissueSync, LabSync, GuideLock markers and 1.4, 1.6 and 1.72 mm Nulty screws in one case.

Request a quotationper unit
View product

Resources

Videos, instructions and files.

Manufacturer resources for your team. They open outside this site.

  • Video

    Watch the introduction

    A quick introduction to Scan Ladder and its place in a full-arch implant workflow.

    Watch the introduction
  • Overview

    How Scan Ladder works

    Understand its role in full-arch digital impressions.

    Read the overview
  • PDF

    Scan Ladder brochure 2025

    The manufacturer’s brochure: design, workflow, range and specifications. English, 0.6 MB.

    Download the brochure
  • Clinical steps

    Scanning instructions

    Follow the manufacturer’s published clinical scanning steps.

    Open instructions
  • CAD

    CAD libraries

    Find the files required for your digital design workflow.

    Open CAD libraries
  • Reference

    Implant compatibility

    Check supported systems and platforms before planning a case.

    Check compatibility
  • Video

    Scan Ladder vs TissueSync™

    See how they differ and when each is used.

    Watch video
  • Video

    GuideLock™ workflow

    See its role in guided surgery and full-arch workflows.

    Watch video
  • Video

    Tips and recommendations

    Practical advice for your scanning workflow.

    Watch video
  • Video

    What is in the Scan Ladder kit?

    See the included components and their uses.

    Watch video

See Scan Ladder in your workflow.

Book a demonstration, request a quotation or ask our team about compatibility with your implant system.

Demonstration and quotation requests are sent from your account; you will be asked to sign in.

Educational links open manufacturer resources or videos outside this site. Confirm compatibility and clinical use against manufacturer instructions.

WhatsApp